Dual Wire Continuous Monitors provide redundancy; even if one dual
wire wrist strap conductor is severed, operator has reliable
path-to-ground with the other wire. Patented Resistance Loop Monitoring Technology
Monitoring of two operators and two ground connections independently
For use with dual-wire wrist straps
Adjustable alarm level
Independent alarming conditions: audible and visual
Resistance, programmable, no manual adjusment necessary
Visual display for all status
Made in America
Note: Work surface must have a conductive layer
such as Dual Layer Rubber or Dissipative 3-Layer Vinyl or Micastat®
Dissipative Laminate with conductive buried layers. Our Continuous
Monitors are not recommended for use with homogeneous matting.
|
|